Determination of the Permissible Range for Surface Resistance of the Outer Corona Protection Systems in High Voltage Electric Machines
نویسندگان :
Hamed Tahanian
1
Zeinab Sadat Sheikholeslami
2
Moein Farhadian
3
AmirAbbas Vahaj
4
Farshad Kiani
5
1- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
2- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
3- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
4- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
5- R&D department Pars Generator and Wind Turbine Engineering and Manufacturing Co.
کلمات کلیدی :
insulation system،high voltage machines،outer corona protection،semiconductive coating،surface resistance
چکیده :
Outer Corona Protection (OCP) is one of the main components of the insulation system in high voltage machines. The main function of OCP is to eliminate high potential differences between the outer surface of the insulated bars (coils) and the grounded stator core in order to avoid surface discharge. To achieve this goal, the surface resistance of the OCP should be lower than a maximum value. However, there are some unpleasant consequences, such as vibration sparking and shorted core laminations, when the OCP is employed. To limit these side effects, other constraints on the maximum and minimum values of the OCP resistance should be considered. This paper tackles this issue from different aspects to provide the acceptable range for the OCP resistance. For this purpose, voltage and current at different positions on the OCP are calculated by analytical formula, taking into account the effects of capacitive currents of the bar insulation and magnetic flux of the stator yoke. Assumptions on the type and number of contact points between the OCP and stator core are made to consider the worst-case scenario. It is shown that the distance of these contact points changes the proper resistance range. Furthermore, the maximum allowed value of this distance is determined. The OCP resistance of a large turbine generator has been calculated by the proposed method. The satisfactory operation of this generator validates the calculation results.
لیست مقالات
لیست مقالات بایگانی شده
استاندارد IEC60422-2024 و تغییرات ایجاد شده
مهدی بیگدلی بیگدلی - سیدعمیدالدین موسوی
Comprehensive Investigation of Conventional and Model-Based Speed Controllers for SPMSM
Ahmad Reza Karamishahnani - Karim Abbaszadeh - Reza Nasiri-Zarandi
A Comparative Study of Foucault Brake System to Consider the Effect of Disc Shape and Material for Increasing Eddy Current Loss and Braking Torque
Hamed Nazifi - Alireza Namnabat - Aref Doroudi
Reduction of End Effect in Linear Variable Reluctance Resolver
Reza Ghorbanalizade - Ramin Alipour-Sarabi - Seyyed Ali Mirabbasi
تشخیص عیب میله شکسته در موتورهای القایی سهفاز با استفاده از طیف فرکانسی مولفه شعاعی شار پراکندگی بیرونی
علیرضا قائم پناه - علی مصلی نژاد - فرهاد حق جو
Robust Wireless Power Transfer by Self-Oscillating Controlled Inverter and Circular Pads
Alireza Eikani - Mohammad Amirkhani - Hossein Jafari - Sadegh Vaez-Zadeh - Mojtaba Mirsalim - Davood Arab Khaburi
Surrogate and Correlation- based Optimization of Out-Rotor PMSM: A Case Study on e-Bike with Enhanced Halbach Array
Ali Amini - Hamidreza Haghighat - Abolfazl Vahedi
کنترل برداری با استفاده از کنترل کننده مدلغزشی برای موتور القایی تک فاز بدون حسگر سرعت با وجود نامعینی های پارامتری موتور
علی جعفری - مهرداد غلامی
Receiving Power Prediction in Wireless Power Transfer Systems Using Deep Learning
Ahmad Sasani - Reza Keypour - Ebrahim Afjei
Comprehensive Investigation on CM Voltage, Bearing Current, and THD in MLI-fed Motor Drives using SPWM
Mohammad Shokrani - Ahmadreza Karami-Shahnani - Karim Abbaszadeh
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 42.3.1